+86 186 0328 1443
Ask About a Model
WFX-220 Atomic Absorption Spectrophotometer (AAS) · WFX-220. Engineering line illustration of analytical instrumentation for M9-2-1, Atomic Spectroscopy, BFRL
WFX-220. Engineering line illustration, not a photograph of the delivered unit.

At a glance

Wavelength Range
170–900 nm
Wavelength Error
≤ ±0.10 nm
Wavelength Repeatability
≤ 0.05 nm
WFX-220AnalyticalM9-2-1Atomic Spectroscopy

Atomic Absorption Spectrophotometer (AAS) · WFX-220

Specifications as published by the manufacturer (BFRL). Parameter names follow international instrument practice; values are reproduced as published.

Technical Specifications

Wavelength Range170–900 nm
Wavelength Error≤ ±0.10 nm
Wavelength Repeatability≤ 0.05 nm
Baseline Stability (static)30 min 漂移 ≤0.002 Abs,噪声 ≤0.001 Abs
Baseline Stability (dynamic)15 min 漂移 ≤0.002 Abs,噪声 ≤0.001 Abs
Spectral Bandwidth Deviation≤ 0.02 nm
Mn Doublet Peak-to-Valley Ratio≤ 25%
Flame Cu Detection Limit≤ 0.002 µg/mL
Flame Cu Characteristic Concentration≤ 0.025 µg/mL/1%
Flame Precision≤ 0.3%
Graphite Furnace Cd Detection Limit≤ 0.4 pg
Graphite Furnace Cd Characteristic Mass≤ 0.5 pg
Graphite Furnace Precision≤ 2.0%
Background Correction (deuterium lamp)1.0 Abs 背景 ≥90 倍
Background Correction (self-absorption)2.0 Abs 背景 ≥90 倍
Graphite Furnace Temperature Range常温~3000 °C
Graphite Furnace Heating Rate≥ 3000 °C/s
Graphite Furnace Temperature Control Accuracy误差 ≤1%
Gas Path System外气 / 内气 / 小气 三气路独立控制
Lamp Positions8 灯位自动旋转灯架
Flame Precision (manufacturer figure)RSD 铜 ≤0.3%(空气-乙炔法)

Parameters reproduced from the manufacturer's published page (source). Source grade B, collected 2026-11-09. Values are reproduced as published, including the original language; no figure has been re-typed or converted.

Key Features

  • 170–900 nm
  • ≤ ±0.10 nm
  • ≤ 0.05 nm
  • 30 min 漂移 ≤0.002 Abs,噪声 ≤0.001 Abs

Where This Model Comes From

Sold on this siteNo. The index does not sell laboratory equipment, takes no commission on it and charges nothing. Nothing here carries a HYSI brand, and no sourcing or procurement service is offered. The buyer orders from the manufacturer named in the row below.
Who makes itThe manufacturer. A complete record has not been published for this model, so the page does not name one.
Who the buyer orders fromThe manufacturer. Price, delivery term, freight and customs entry are agreed between the buyer and the manufacturer.
PriceNot published here, and no price range is given: this index does not quote. Price is set by the manufacturer against the configuration, the destination country and the certification required. The manufacturer's own email address and telephone number are in the table above; write to the factory with the model and the quantity. The equipment as supplied may not meet the certification requirements of the buyer's country.
What is on requestThe full parameter table and the certification documents the manufacturer issues.

Certification and Where the Equipment Can Be Sold

Model-level certificatesNone published. No manufacturer record is held for this model.
Management system, held by the manufacturerNone published.
Standards the parameters refer toNot stated on this page.
Markets the certificates on record supportNo market is claimed. A management-system certificate authorises no sale in any market. The EU and EEA require a model-level declaration of conformity and an EU responsible person; the United Kingdom requires UKCA marking; the United States and Canada require UL or CSA listing where the authority having jurisdiction asks for it.
Where the answer comes fromThe manufacturer, in writing. No manufacturer record is published for this model yet.

This index repeats only what the manufacturer has published. Where nothing is published, the row says so rather than leaving a claim standing.

Frequently Asked Questions

What is the WFX-220 Atomic Absorption Spectrophotometer (AAS) · WFX-220?

WFX-220 is a atomic absorption spectrophotometer (aas) · wfx-220 listed in the HYSI catalogue. Specifications as published by the manufacturer (BFRL). Parameter names follow international instrument practice; values are reproduced as published.

Who should buy the WFX-220?

It suits laboratories working with m9-2-1, atomic spectroscopy, bfrl, typically universities, research institutes, enterprise R&D centres and third-party testing laboratories.

Does this page show a price?

No. This index does not quote and gives no price range. Price is set by the manufacturer against the configuration, the destination country and the certification required. The contact block below carries the maker's own email address and telephone number: write to the factory with the model and the quantity, and the answer comes from the party that sets the price.

Is the voltage compatible with my country?

The manufacturer states the voltage build. A 220 V/50 Hz build, a 187-253 V wide-range build and a 100-240 V build are not interchangeable, and the parameter table states which one a model uses.

What documents are provided with the shipment?

The packing list, the factory inspection report and the customs documents are issued by the manufacturer. FAT and PSI reports depend on the maker and on the project.

The full parameter table and the certification documents the manufacturer issues are obtained from the manufacturer.

Related Products

WQF-530 Fourier Transform Infrared Spectrometer (FTIR) · WQF-530. Engineering line illustration of analytical instrumentation for M9-2-3, Molecular Spectroscopy, BFRL Analytical
WQF-530

Fourier Transform Infrared Spectrometer (FTIR) · WQF-530

Specifications as published by the manufacturer (BFRL). Parameter names follow international instrument practice; values are reproduced as published.

CS-910 Carbon/Sulfur Determinator · CS-910. Manufacturer product photograph Analytical
CS-910

Carbon/Sulfur Determinator · CS-910

Specifications as published by the manufacturer (GLMY). Parameter names follow international instrument practice; values are reproduced as published.

CAN400 Nuclear Magnetic Resonance Spectrometer (NMR) · CAN400. Engineering line illustration of analytical instrumentation for M9-5-1, Magnetic Resonance, CIQTEK Analytical
CAN400

Nuclear Magnetic Resonance Spectrometer (NMR) · CAN400

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

CAN600 Nuclear Magnetic Resonance Spectrometer (NMR) · CAN600. Manufacturer product photograph Analytical
CAN600

Nuclear Magnetic Resonance Spectrometer (NMR) · CAN600

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

Ask about a parameter, a source, or a row in the manufacturer index

Questions about what a figure means, where it came from, or why a model is listed as it is are answered by the index. Questions about price, delivery or configuration are answered by the manufacturer; the model page carries the number to call.

Send a question