+86 186 0328 1443
Ask About a Model

Sample Preparation Equipment

Digestion, extraction, concentration, grinding and homogenizing, for food, environmental, pharmaceutical and materials testing. Vessel, insert and seal are specified from the sample, the acid and the batch size.

TOPEX+ Microwave Digestion Platform, 40-Vessel. Engineering line illustration of sample preparation equipment for Digestion, Acid, Trace Analysis Pre-treatment
TOPEX+

Microwave Digestion Platform, 40-Vessel

A microwave digestion platform with a 316L stainless cavity coated in PFA and a 2450 MHz source. Up to forty vessels run in one batch, each rated to at least 103 bar and 300 °C, with both platinum-resistance and mid-infrared temperature sensing plus contact pressure monitoring. Methods number 200 or more and the last ten hours of runs are retained. 3200 W installed.

SOX406 Soxhlet Fat Extractor, 6-Place. Engineering line illustration of sample preparation equipment for Extraction, Fat Content, Organic Pre-treatment
SOX406

Soxhlet Fat Extractor, 6-Place

A six-place Soxhlet extractor for fat determination, with a sealed metal-bath heater running room temperature +5 to 280 °C at ±1 °C. Each batch takes six 80 mL solvent cups; solvent recovery is stated at 80% or better and the extraction is quoted as 20 to 80% shorter than the classical method. The electrical compartment is isolated from the extraction space.

SCIENTZ-IID Ultrasonic Cell Disruptor, 1000 W. Engineering line illustration of sample preparation equipment for Cell Disruption, Homogenizing, Ultrasonic Pre-treatment
SCIENTZ-IID

Ultrasonic Cell Disruptor, 1000 W

An ultrasonic cell disruptor with automatic frequency tracking between 20 and 25 kHz and power adjustable from 20 to 1000 W. It handles 100 µL to 600 mL with a Φ6 mm probe as standard and Φ2, Φ3, Φ10 and Φ15 mm probes optional. Duty cycle 0.1 to 99.9%, timer 1 to 999 minutes, twenty stored programs, 7-inch touch screen.

FA25 High-Shear Disperser, 500 W. Engineering line illustration of sample preparation equipment for Homogenizing, Blending, Sample Prep Pre-treatment
FA25

High-Shear Disperser, 500 W

A laboratory high-shear disperser with a 500 W motor running 10,000 to 28,000 rpm and a tip speed of 27 m/s, handling 0.2 to 7,000 mL at up to 8,000 cP. The 25F dispersing tool is standard; wetted parts are SS316L with a PTFE bearing. Interchangeable tools cover dispersion, emulsification, homogenisation, wet milling and tissue disruption. 220 V.

LJ-GSH Multi-Tube Vortex Mixer, 16/28-Position. Engineering line illustration of sample preparation equipment for Mixing, Vortex, Sample Prep Pre-treatment
LJ-GSH

Multi-Tube Vortex Mixer, 16/28-Position

A multi-tube vortex mixer running 300 to 4000 rpm with a 3 mm amplitude, taking sixteen tubes of 16 to 32 mm or twenty-eight tubes of 9 to 18 mm in one load up to 800 g. Speed is shown digitally at 10 rpm resolution and the timer runs 1 to 1999 minutes or continuously; more than six programs can be stored. 220 V, 25 kg.

ZQM-2L Planetary Ball Mill, 4-Station, 2 L. Engineering line illustration of sample preparation equipment for Grinding, Milling, Powder Pre-treatment
ZQM-2L

Planetary Ball Mill, 4-Station, 2 L

A four-station planetary ball mill for dry, wet, vacuum and atmosphere-protected grinding, with revolution from 5 to 400 rpm and rotation from 10 to 800 rpm at a fixed 1:2 ratio. Jars run from 50 to 500 mL; feed size is under 5 mm (under 10 mm for soil). Three running modes and fifteen stored programs, 0.75 kW on single-phase 220 V.

SH220F Graphite Digestion Block, 20-Place. Engineering line illustration of sample preparation equipment for Nitrogen, Protein, Digestion Pre-treatment
SH220F

Graphite Digestion Block, 20-Place

A graphite digestion block for Kjeldahl and metals preparation, taking twenty 300 mL tubes per batch over a working range of room temperature +5 to 450 °C with ±1 °C control. Heating is infrared through a high-purity graphite block; ten digestion programs can be stored, each with up to five temperature and time steps. 3.6 kW at 220 V.

GSL-1100X Tube Furnace, 1100 ℃, 900 mm Heating Zone. Engineering line illustration of sample preparation equipment for Ashing, Sintering, Heat Treatment Pre-treatment
GSL-1100X

Tube Furnace, 1100 ℃, 900 mm Heating Zone

A horizontal tube furnace with a 900 mm heating zone, 1050 °C maximum for short holds and 1000 °C continuous, ramping at 10 °C per minute or less with ±1 °C control over thirty programmable segments. The Φ11-inch by 1320 mm tube closes on water-cooled stainless flanges with silicone O-rings; a mechanical gauge covers −0.1 to 0.15 MPa and a safety valve opens at 0.02 MPa. 11 kW at 220 V.

S1 Sub-Boiling Acid Purification System. Engineering line illustration of sample preparation equipment for Acid Purification, Distillation, Trace Pre-treatment
S1

Sub-Boiling Acid Purification System

A sub-boiling acid purification system that distils nitric, hydrochloric and hydrofluoric acid and water without quartz or metal in the wetted path. The heated stage runs to 200 °C at 300 W, taking 0.5 to 2 L of acid per batch, and yields 1.8 L of nitric acid per 24 hours at a distillation rate of 1.25 mL per minute into a 500 mL collecting bottle.

M32 Automated Parallel Concentrator, 32-Channel. Engineering line illustration of sample preparation equipment for Evaporation, Concentration, Solvent Pre-treatment
M32

Automated Parallel Concentrator, 32-Channel

A 32-channel parallel concentrator combining a water bath with nitrogen blow-down. Needles follow the liquid level down and rise automatically at the end of the run; nitrogen pressure is program-controlled so opening or closing channels does not change the flow. The lid locks during concentration and releases gas when opened. Temperature range room to 100 °C at ±1 °C, 7-inch touch screen.

SCIENTZ-4TD PRO Multi-Channel Ultrasonic Cell Disruptor, 1 to 100%. Engineering line illustration of sample preparation equipment for Multi-Channel Ultrasonic Cell Disruptor, Laboratory Pre-treatment
SCIENTZ-4TD PRO

Multi-Channel Ultrasonic Cell Disruptor, 1 to 100%

Multi-Channel Ultrasonic Cell Disruptor. power 1 to 100%; ultrasonic power 650W*4.

SCIENTZ-6TD PRO Multi-Channel Ultrasonic Cell Disruptor, 1 to 100% (1). Engineering line illustration of sample preparation equipment for Multi-Channel Ultrasonic Cell Disruptor, Laboratory Pre-treatment
SCIENTZ-6TD PRO

Multi-Channel Ultrasonic Cell Disruptor, 1 to 100% (1)

Multi-Channel Ultrasonic Cell Disruptor. power 1 to 100%; ultrasonic power 650W*6.

SCIENTZ-8TD PRO Multi-Channel Ultrasonic Cell Disruptor, 1 to 100% (2). Engineering line illustration of sample preparation equipment for Multi-Channel Ultrasonic Cell Disruptor, Laboratory Pre-treatment
SCIENTZ-8TD PRO

Multi-Channel Ultrasonic Cell Disruptor, 1 to 100% (2)

Multi-Channel Ultrasonic Cell Disruptor. power 1 to 100%; ultrasonic power 650W*8.

Questions Buyers Ask About This Range

Which sample preparation methods does this range cover?

Microwave and Kjeldahl digestion, Soxhlet and accelerated solvent extraction, nitrogen blowdown, vortex mixing, homogenizing, planetary ball milling, ultrasonic crushing and acid distillation. Inorganic and organic sample preparation for food, environmental, pharmaceutical and materials testing.

Should I choose microwave digestion or Kjeldahl digestion?

Microwave digestion is used when the sample has to be fully dissolved in acid before trace-metal measurement by ICP or AAS. Kjeldahl digestion is used for nitrogen and protein determination. Measuring metals points to microwave; measuring protein content points to Kjeldahl.

How are vessels and accessories matched to my samples?

Vessel material, volume and pressure rating depend on the sample type, the acid and the batch size. The manufacturer confirms the vessel, insert and seal specification in writing, and quotes consumables with the instrument.

Can the whole sample preparation line be supplied as one project?

Yes. Digestion, extraction, concentration and clean-up can be assembled as a single laboratory package with one documentation set, one shipping plan and one point of contact.

The configuration the buyer needs is not listed?

Custom specifications and matched accessories are matters for the manufacturer. The index states which model the manufacturer publishes and what the parameter table does not cover.

Ask About This Range