Magnetic Field Strength
9.39 Tesla
Room-temperature Bore Diameter
54 mm
Transmit/Receive Channels
默认 2 个,可拓展到 8 个
CAN400AnalyticalM9-5-1Magnetic Resonance

Nuclear Magnetic Resonance Spectrometer (NMR) · CAN400

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

Technical Specifications

Magnetic Field Strength9.39 Tesla
Room-temperature Bore Diameter54 mm
Transmit/Receive Channels默认 2 个,可拓展到 8 个
Time Resolution4 ns
Minimum Event Time4 ns
Phase Resolution0.001°
Operating SystemWindows
Languages中文,英文
Supported Experiments一维、二维等核磁共振实验的数据采集及谱图处理功能
Experimental Data包含常用核磁实验方法,支持主流实验数据格式读取,数据可存为通用格式
Pulse Sequence Simulation脉冲序列编写和图形化界面
Type72位自动进样器
Rotation Direction双向旋转
Rapid Sample Change具备快速预进样装置

Parameters reproduced from the manufacturer's published page (source). Source grade A1, collected 2026-11-14. Values are reproduced as published, including the original language; no figure has been re-typed or converted.

Key Features

  • 9.39 Tesla
  • 54 mm
  • 默认 2 个,可拓展到 8 个
  • 4 ns

Where This Model Comes From

Sold on this siteNo. The index does not sell laboratory equipment, takes no commission on it and charges nothing. Nothing here carries a HYSI brand, and no sourcing or procurement service is offered. The buyer orders from the manufacturer named in the row below.
Who makes itThe manufacturer. A complete record has not been published for this model, so the page does not name one.
Who the buyer orders fromThe manufacturer. Price, delivery term, freight and customs entry are agreed between the buyer and the manufacturer.
PriceNot published here, and no price range is given: this index does not quote. Price is set by the manufacturer against the configuration, the destination country and the certification required. The manufacturer's own email address and telephone number are in the table above; write to the factory with the model and the quantity. The equipment as supplied may not meet the certification requirements of the buyer's country.
What is on requestThe full parameter table and the certification documents the manufacturer issues.

Certification and Where the Equipment Can Be Sold

Model-level certificatesNone published. No manufacturer record is held for this model.
Management system, held by the manufacturerNone published.
Standards the parameters refer toNot stated on this page.
Markets the certificates on record supportNo market is claimed. A management-system certificate authorises no sale in any market. The EU and EEA require a model-level declaration of conformity and an EU responsible person; the United Kingdom requires UKCA marking; the United States and Canada require UL or CSA listing where the authority having jurisdiction asks for it.
Where the answer comes fromThe manufacturer, in writing. No manufacturer record is published for this model yet.

This index repeats only what the manufacturer has published. Where nothing is published, the row says so rather than leaving a claim standing.

Frequently Asked Questions

What is the CAN400 Nuclear Magnetic Resonance Spectrometer (NMR) · CAN400?

CAN400 is a nuclear magnetic resonance spectrometer (nmr) · can400 listed in the HYSI catalogue. Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

Who should buy the CAN400?

It suits laboratories working with m9-5-1, magnetic resonance, ciqtek, typically universities, research institutes, enterprise R&D centres and third-party testing laboratories.

Does this page show a price?

No. This index does not quote and gives no price range. Price is set by the manufacturer against the configuration, the destination country and the certification required. The contact block below carries the maker's own email address and telephone number: write to the factory with the model and the quantity, and the answer comes from the party that sets the price.

Is the voltage compatible with my country?

The manufacturer states the voltage build. A 220 V/50 Hz build, a 187-253 V wide-range build and a 100-240 V build are not interchangeable, and the parameter table states which one a model uses.

What documents are provided with the shipment?

The packing list, the factory inspection report and the customs documents are issued by the manufacturer. FAT and PSI reports depend on the maker and on the project.

The full parameter table and the certification documents the manufacturer issues are obtained from the manufacturer.

Related Products

CAN600 Nuclear Magnetic Resonance Spectrometer (NMR) · CAN600. Manufacturer product photograph Analytical
CAN600

Nuclear Magnetic Resonance Spectrometer (NMR) · CAN600

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

DB550X Field Emission Scanning Electron Microscope (FE-SEM) · DB550X. Engineering line illustration of analytical instrumentation for M9-4-1, Electron Microscopy, CIQTEK Analytical
DB550X

Field Emission Scanning Electron Microscope (FE-SEM) · DB550X

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

EPR-Q400 Electron Paramagnetic Resonance Spectrometer (EPR) · EPR-Q400. Manufacturer product photograph Analytical
EPR-Q400

Electron Paramagnetic Resonance Spectrometer (EPR) · EPR-Q400

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

EPR-W900 Electron Paramagnetic Resonance Spectrometer (EPR) · EPR-W900. Engineering line illustration of analytical instrumentation for M9-5-3, Magnetic Resonance, CIQTEK Analytical
EPR-W900

Electron Paramagnetic Resonance Spectrometer (EPR) · EPR-W900

Specifications as published by the manufacturer (CIQTEK). Parameter names follow international instrument practice; values are reproduced as published.

Ask about a parameter, a source, or a row in the manufacturer index

Questions about what a figure means, where it came from, or why a model is listed as it is are answered by the index. Questions about price, delivery or configuration are answered by the manufacturer; the model page carries the number to call.

Send a question