+86 186 0328 1443
Get a Quote

Cold Chain & Low-Temperature Storage

Refrigerators at 2–8 °C, −25 °C and −40 °C freezers, −86 °C ultra-low temperature freezers, liquid nitrogen storage, cold-chain accessories and incubators — specified by temperature band, volume and sample format, not by brand.

Find a Product by Its Shape

Click an illustration to show only that type of machine.

HYSI-CLD-UF860 -86 to -40 °C, Ultra-Low Temperature Freezer, 860 L — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF860

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 860 L.

HYSI-CLD-UF860G -86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Touchscreen — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF860G

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Touchscreen

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Touchscreen — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 860 L.

HYSI-CLD-UF860P -86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Inverter — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF860P

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Inverter

-86 to -40 °C, Ultra-Low Temperature Freezer, 860 L, Inverter — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 860 L.

HYSI-CLD-UF850 -86 to -40 °C, Ultra-Low Temperature Freezer, 850 L — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF850

-86 to -40 °C, Ultra-Low Temperature Freezer, 850 L

-86 to -40 °C, Ultra-Low Temperature Freezer, 850 L — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 850 L.

HYSI-CLD-UF850P -86 to -40 °C, Ultra-Low Temperature Freezer, 850 L, Inverter — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF850P

-86 to -40 °C, Ultra-Low Temperature Freezer, 850 L, Inverter

-86 to -40 °C, Ultra-Low Temperature Freezer, 850 L, Inverter — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 850 L.

HYSI-CLD-UF585 -86 to -40 °C, Ultra-Low Temperature Freezer, 585 L — engineering line illustration of cold-chain storage equipment for Ultra-Low Temperature, −60 to −86 °C Cold Chain
HYSI-CLD-UF585

-86 to -40 °C, Ultra-Low Temperature Freezer, 585 L

-86 to -40 °C, Ultra-Low Temperature Freezer, 585 L — Ultra-Low Temperature Freezers (−60 ~ −86 °C). -86 to -40 °C; 585 L.

HYSI-CLD-AC007 Low-Temperature Workbench — engineering line illustration of cold-chain storage equipment for Cold-Chain Accessory, Storage & Handling Cold Chain
HYSI-CLD-AC007

Low-Temperature Workbench

Low-Temperature Workbench — Cold-Chain Accessories.

HYSI-CLD-AC008 Low-Temperature Cold Room — engineering line illustration of cold-chain storage equipment for Cold-Chain Accessory, Storage & Handling Cold Chain
HYSI-CLD-AC008

Low-Temperature Cold Room

Low-Temperature Cold Room — Cold-Chain Accessories.

HYSI-CLD-AC009 Automatic Defroster — engineering line illustration of cold-chain storage equipment for Cold-Chain Accessory, Storage & Handling Cold Chain
HYSI-CLD-AC009

Automatic Defroster

Automatic Defroster — Cold-Chain Accessories.

HYSI-CLD-AC010 Automatic Defroster — engineering line illustration of cold-chain storage equipment for Cold-Chain Accessory, Storage & Handling Cold Chain
HYSI-CLD-AC010

Automatic Defroster

Automatic Defroster — Cold-Chain Accessories.

HYSI-CLD-LF620P -40 to 2 °C, Refrigerator / Freezer, 620 L, Inverter — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF620P

-40 to 2 °C, Refrigerator / Freezer, 620 L, Inverter

-40 to 2 °C, Refrigerator / Freezer, 620 L, Inverter — Low-Temperature Freezers (−25 ~ −40 °C). -40 to 2 °C; 620 L.

HYSI-CLD-LF590P -40 to -20 °C, Low-Temperature Freezer, 590 L, Inverter — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF590P

-40 to -20 °C, Low-Temperature Freezer, 590 L, Inverter

-40 to -20 °C, Low-Temperature Freezer, 590 L, Inverter — Low-Temperature Freezers (−25 ~ −40 °C). -40 to -20 °C; 590 L.

HYSI-CLD-LF575S -40 to -20 °C, Low-Temperature Freezer, 575 L, Stainless Interior — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF575S

-40 to -20 °C, Low-Temperature Freezer, 575 L, Stainless Interior

-40 to -20 °C, Low-Temperature Freezer, 575 L, Stainless Interior — Low-Temperature Freezers (−25 ~ −40 °C). -40 to -20 °C; 575 L.

HYSI-CLD-LF568 -25 to -15 °C, Low-Temperature Freezer, 568 L — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF568

-25 to -15 °C, Low-Temperature Freezer, 568 L

-25 to -15 °C, Low-Temperature Freezer, 568 L — Low-Temperature Freezers (−25 ~ −40 °C). -25 to -15 °C; 568 L.

HYSI-CLD-LF500P -30 to -15 °C, Low-Temperature Freezer, 500 L, Inverter — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF500P

-30 to -15 °C, Low-Temperature Freezer, 500 L, Inverter

-30 to -15 °C, Low-Temperature Freezer, 500 L, Inverter — Low-Temperature Freezers (−25 ~ −40 °C). -30 to -15 °C; 500 L.

HYSI-CLD-LF458T -25 to -15 °C, Low-Temperature Freezer, 458 L, Bench-Top — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF458T

-25 to -15 °C, Low-Temperature Freezer, 458 L, Bench-Top

-25 to -15 °C, Low-Temperature Freezer, 458 L, Bench-Top — Low-Temperature Freezers (−25 ~ −40 °C). -25 to -15 °C; 458 L.

HYSI-CLD-LF450P -40 to 2 °C, Refrigerator / Freezer, 450 L, Inverter — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF450P

-40 to 2 °C, Refrigerator / Freezer, 450 L, Inverter

-40 to 2 °C, Refrigerator / Freezer, 450 L, Inverter — Low-Temperature Freezers (−25 ~ −40 °C). -40 to 2 °C; 450 L.

HYSI-CLD-LF368 -25 to -15 °C, Low-Temperature Freezer, 368 L — engineering line illustration of cold-chain storage equipment for Low-Temperature, −25 to −40 °C Cold Chain
HYSI-CLD-LF368

-25 to -15 °C, Low-Temperature Freezer, 368 L

-25 to -15 °C, Low-Temperature Freezer, 368 L — Low-Temperature Freezers (−25 ~ −40 °C). -25 to -15 °C; 368 L.

HYSI-CLD-AC019 Transport Trolley — engineering line illustration of cold-chain storage equipment for Cold-Chain Accessory, Storage & Handling Cold Chain
HYSI-CLD-AC019

Transport Trolley

Transport Trolley — Cold-Chain Accessories.

HYSI-CLD-RF1150 2 to 8 °C, Refrigerator, 1150 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF1150

2 to 8 °C, Refrigerator, 1150 L

2 to 8 °C, Refrigerator, 1150 L — Refrigerators (2–8 °C). 2 to 8 °C; 1150 L.

HYSI-CLD-RF795 2 to 8 °C, Refrigerator, 795 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF795

2 to 8 °C, Refrigerator, 795 L

2 to 8 °C, Refrigerator, 795 L — Refrigerators (2–8 °C). 2 to 8 °C; 795 L.

HYSI-CLD-RF635 2 to 8 °C, Refrigerator, 635 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF635

2 to 8 °C, Refrigerator, 635 L

2 to 8 °C, Refrigerator, 635 L — Refrigerators (2–8 °C). 2 to 8 °C; 635 L.

HYSI-CLD-RF455 2 to 8 °C, Refrigerator, 455 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF455

2 to 8 °C, Refrigerator, 455 L

2 to 8 °C, Refrigerator, 455 L — Refrigerators (2–8 °C). 2 to 8 °C; 455 L.

HYSI-CLD-RF395 2 to 8 °C, Refrigerator, 395 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF395

2 to 8 °C, Refrigerator, 395 L

2 to 8 °C, Refrigerator, 395 L — Refrigerators (2–8 °C). 2 to 8 °C; 395 L.

HYSI-CLD-RF150 2 to 8 °C, Refrigerator, 150 L — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF150

2 to 8 °C, Refrigerator, 150 L

2 to 8 °C, Refrigerator, 150 L — Refrigerators (2–8 °C). 2 to 8 °C; 150 L.

HYSI-CLD-RF026 2 to 8 °C, Refrigerator — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF026

2 to 8 °C, Refrigerator

2 to 8 °C, Refrigerator — Refrigerators (2–8 °C). 2 to 8 °C.

HYSI-CLD-RF027 2 to 8 °C, Refrigerator — engineering line illustration of cold-chain storage equipment for Refrigerator, 2–8 °C Cold Chain
HYSI-CLD-RF027

2 to 8 °C, Refrigerator

2 to 8 °C, Refrigerator — Refrigerators (2–8 °C). 2 to 8 °C.

HYSI-CLD-INC028 Biological Safety Cabinet — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC028

Biological Safety Cabinet

Biological Safety Cabinet — Incubators & Clean Equipment.

HYSI-CLD-INC029 CO₂ Incubator — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC029

CO₂ Incubator

CO₂ Incubator — Incubators & Clean Equipment.

HYSI-CLD-INC030G Electric Heating Incubator, Touchscreen — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC030G

Electric Heating Incubator, Touchscreen

Electric Heating Incubator, Touchscreen — Incubators & Clean Equipment.

HYSI-CLD-INC031 Electric Heating Incubator — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC031

Electric Heating Incubator

Electric Heating Incubator — Incubators & Clean Equipment.

HYSI-CLD-INC032 Forced-Air Drying Oven — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC032

Forced-Air Drying Oven

Forced-Air Drying Oven — Incubators & Clean Equipment.

HYSI-CLD-INC033 Forced-Air Drying Oven — engineering line illustration of cold-chain storage equipment for Incubator, Clean Equipment Cold Chain
HYSI-CLD-INC033

Forced-Air Drying Oven

Forced-Air Drying Oven — Incubators & Clean Equipment.

Questions Buyers Ask About This Range

Which temperature band do I need for my samples?

Match the band to the sample, not the other way round: vaccines, reagents, blood products and clinical specimens normally need 2-8 °C; general frozen storage of reagents and intermediates needs −20 °C to −40 °C; cells, plasma, DNA/RNA and reference material for long-term archiving need −60 °C to −86 °C; and only liquid nitrogen at −196 °C is suitable for long-term cell-line and primary-sample banking.

What is the difference between an upright and a chest freezer?

An upright freezer occupies less floor space, keeps samples on shelves and gives the fastest access, but cold air spills each time the door opens. A chest freezer holds the cold far better during power failure or frequent access and is preferred where the same samples are handled all day. Volume, doorway width and how often the door is opened decide which one is right.

What information do you need to shortlist a model?

Four points: the temperature band required, the volume to be stored, the sample format (2 mL cryovials, bags, bottles or plates) and the number of door openings per day. With those we can quote the model, the shelf or rack layout, the cryovial capacity and the correct mains configuration.

Are spare racks, shelves and inner doors available?

Yes. Storage racks, drawers, inner doors, cryovial boxes and caster sets are quoted together with the unit so the freezer arrives ready to load, and consumables can be re-ordered later against the same stock code.

Not sure which configuration suits your samples?

Tell us your sample volume, solvent type and target analytes. Our specialists prepare a configuration proposal — you choose the final technical solution.

Request a Configuration Proposal