+86 186 0328 1443
Ask About a Model
ZQM-2L Planetary Ball Mill, 4-Station, 2 L. Engineering line illustration of sample preparation equipment for Grinding, Milling, Powder
ZQM-2L. Engineering line illustration, not a photograph of the delivered unit.

At a glance

Grinding stations
4 个研磨平台
Jar volume
50 ~ 500 mL(单罐)
Vacuum jar volume
50 ~ 250 mL
ZQM-2LSample PreparationGrindingMilling

Planetary Ball Mill, 4-Station, 2 L

A four-station planetary ball mill for dry, wet, vacuum and atmosphere-protected grinding, with revolution from 5 to 400 rpm and rotation from 10 to 800 rpm at a fixed 1:2 ratio. Jars run from 50 to 500 mL; feed size is under 5 mm (under 10 mm for soil). Three running modes and fifteen stored programs, 0.75 kW on single-phase 220 V.

Technical Specifications

Grinding stations4 个研磨平台
Jar volume50 ~ 500 mL(单罐)
Vacuum jar volume50 ~ 250 mL
Revolution speed5 ~ 400 r/min
Rotation speed10 ~ 800 r/min
Speed ratio1 : 2
Max feed size<5 mm(土壤 <10 mm)
Grinding modes干磨、湿磨、真空磨、气氛保护磨
运行模式单向、交替正反转、多段式
Stored programs15 个
Time setting0 ~ 9999 min(运行/停歇分别设定)
Power consumption0.75 kW
Power supply单相 220 V,50 Hz
Dimensions715 × 495 × 630 mm
Net weight98 kg

Key Features

  • Belt-drive design, low noise and long life
  • Rapid grinding with high reduction ratio
  • Abrasion-resistant jars & media options
  • Reverse and pause functions for process control

Where This Model Comes From

Sold on this siteNo. The index does not sell laboratory equipment, takes no commission on it and charges nothing. Nothing here carries a HYSI brand, and no sourcing or procurement service is offered. The buyer orders from the manufacturer named in the row below.
Who makes itThe manufacturer. A complete record has not been published for this model, so the page does not name one.
Who the buyer orders fromThe manufacturer. Price, delivery term, freight and customs entry are agreed between the buyer and the manufacturer.
PriceNot published here, and no price range is given: this index does not quote. Price is set by the manufacturer against the configuration, the destination country and the certification required. The manufacturer's own email address and telephone number are in the table above; write to the factory with the model and the quantity. The equipment as supplied may not meet the certification requirements of the buyer's country.
What is on requestThe full parameter table and the certification documents the manufacturer issues.

Certification and Where the Equipment Can Be Sold

Model-level certificatesNone published. No manufacturer record is held for this model.
Management system, held by the manufacturerNone published.
Standards the parameters refer toNot stated on this page.
Markets the certificates on record supportNo market is claimed. A management-system certificate authorises no sale in any market. The EU and EEA require a model-level declaration of conformity and an EU responsible person; the United Kingdom requires UKCA marking; the United States and Canada require UL or CSA listing where the authority having jurisdiction asks for it.
Where the answer comes fromThe manufacturer, in writing. No manufacturer record is published for this model yet.

This index repeats only what the manufacturer has published. Where nothing is published, the row says so rather than leaving a claim standing.

Frequently Asked Questions

What is the ZQM-2L Planetary Ball Mill, 4-Station, 2 L?

ZQM-2L is a planetary ball mill, 4-station, 2 l listed in the HYSI catalogue. A four-station planetary ball mill for dry, wet, vacuum and atmosphere-protected grinding, with revolution from 5 to 400 rpm and rotation from 10 to 800 rpm at a fixed 1:2 ratio. Jars run from 50 to 500 mL; feed size is under 5 mm (under 10 mm for soil). Three running modes and fifteen stored programs, 0.75 kW on single-phase 220 V.

Who should buy the ZQM-2L?

It suits laboratories working with grinding, milling, powder, typically universities, research institutes, enterprise R&D centres and third-party testing laboratories.

Does this page show a price?

No. This index does not quote and gives no price range. Price is set by the manufacturer against the configuration, the destination country and the certification required. The contact block below carries the maker's own email address and telephone number: write to the factory with the model and the quantity, and the answer comes from the party that sets the price.

Is the voltage compatible with my country?

The manufacturer states the voltage build. A 220 V/50 Hz build, a 187-253 V wide-range build and a 100-240 V build are not interchangeable, and the parameter table states which one a model uses.

What documents are provided with the shipment?

The packing list, the factory inspection report and the customs documents are issued by the manufacturer. FAT and PSI reports depend on the maker and on the project.

The full parameter table and the certification documents the manufacturer issues are obtained from the manufacturer.

Related Products

SH220F Graphite Digestion Block, 20-Place. Engineering line illustration of sample preparation equipment for Nitrogen, Protein, Digestion Pre-treatment
SH220F

Graphite Digestion Block, 20-Place

A graphite digestion block for Kjeldahl and metals preparation, taking twenty 300 mL tubes per batch over a working range of room temperature +5 to 450 °C with ±1 °C control. Heating is infrared through a high-purity graphite block; ten digestion programs can be stored, each with up to five temperature and time steps. 3.6 kW at 220 V.

GSL-1100X Tube Furnace, 1100 ℃, 900 mm Heating Zone. Engineering line illustration of sample preparation equipment for Ashing, Sintering, Heat Treatment Pre-treatment
GSL-1100X

Tube Furnace, 1100 ℃, 900 mm Heating Zone

A horizontal tube furnace with a 900 mm heating zone, 1050 °C maximum for short holds and 1000 °C continuous, ramping at 10 °C per minute or less with ±1 °C control over thirty programmable segments. The Φ11-inch by 1320 mm tube closes on water-cooled stainless flanges with silicone O-rings; a mechanical gauge covers −0.1 to 0.15 MPa and a safety valve opens at 0.02 MPa. 11 kW at 220 V.

S1 Sub-Boiling Acid Purification System. Engineering line illustration of sample preparation equipment for Acid Purification, Distillation, Trace Pre-treatment
S1

Sub-Boiling Acid Purification System

A sub-boiling acid purification system that distils nitric, hydrochloric and hydrofluoric acid and water without quartz or metal in the wetted path. The heated stage runs to 200 °C at 300 W, taking 0.5 to 2 L of acid per batch, and yields 1.8 L of nitric acid per 24 hours at a distillation rate of 1.25 mL per minute into a 500 mL collecting bottle.

M32 Automated Parallel Concentrator, 32-Channel. Engineering line illustration of sample preparation equipment for Evaporation, Concentration, Solvent Pre-treatment
M32

Automated Parallel Concentrator, 32-Channel

A 32-channel parallel concentrator combining a water bath with nitrogen blow-down. Needles follow the liquid level down and rise automatically at the end of the run; nitrogen pressure is program-controlled so opening or closing channels does not change the flow. The lid locks during concentration and releases gas when opened. Temperature range room to 100 °C at ±1 °C, 7-inch touch screen.

Ask about a parameter, a source, or a row in the manufacturer index

Questions about what a figure means, where it came from, or why a model is listed as it is are answered by the index. Questions about price, delivery or configuration are answered by the manufacturer; the model page carries the number to call.