Cold traps: do the buyer needs one, and how cold

Every vacuum evaporation pulls solvent vapour out of the chamber, and something has to stop it before it reaches the pump. A cold trap does that job. The decision is whether the buyer needs one at all, and then how much colder than the solvent it has to be.

A cold trap is a refrigerated surface placed between the vacuum chamber and the pump. Vapour that reaches it condenses on the coil and stays there. It does two jobs at once: it protects the pump from what the vapour would otherwise do to it, and it collects the solvent in a form the buyer can pour away.

What the trap is protecting

The pump sees everything the chamber releases. On a diaphragm pump that means the gas path, the valves and the head; on an oil pump it also means the oil, which stops doing its job once it has absorbed a solvent.

Corrosion is the second concern and the slower one. An acid digest or a chlorinated solvent puts vapour through the same path, and the head of a standard pump will not last through a routine programme.

This is why the gas path has to be specified alongside the trap rather than after it. HYSI's corrosion-resistant diaphragm pump is rated to an ultimate pressure of 7 mbar with a pumping speed of 28 L per minute, and it belongs on the same order as the trap for that reason.

How cold: the vapour pressure question

The right trap temperature is the one at which the solvent's vapour pressure is low enough that it stays on the coil instead of travelling on to the pump. Water and the common laboratory solvents reach that point within the range the three models in HYSI's catalogue cover.

The −50 °C unit handles the bulk of routine work. The −60 °C unit buys margin, which matters when the chamber runs at lower pressure, when the solvent is a volatile one, or when a single trap serves more than one instrument.

The −80 °C unit is for the cases where the margin is not a preference but a requirement: very volatile solvents, low-pressure processes, and methods that have to hold a cold surface well below what a standard refrigeration circuit reaches.

If the buyer is still settling the evaporation side of the method, the guide to centrifugal vacuum concentrators works through the chamber, the vacuum and the pump in the order HYSI asks for them.

Capacity, and why a full trap is a slow trap

All three traps in HYSI's catalogue holds 2000 mL. Capacity is sized against the solvent volume of a batch, not against a day.

Frost build-up is the part that gets ignored. Ice insulates the coil, and a coil that is half covered condenses less efficiently than a clean one. The symptom is a programme that gradually takes longer, which is usually blamed on the pump.

Defrost between batches rather than at the end of the day, and keep the batch volume inside the capacity of the trap. A trap that fills during a run has nowhere to put the rest of the vapour.

Power and heat where the bench is

Going colder costs power, and the figures in HYSI's catalogue shows how the step scales. The −50 °C and −60 °C units draw 450 W and 500 W. The −80 °C unit draws 1000 W, and it is a larger cabinet as well, at 620 mm by 450 mm by 400 mm against 500 mm by 210 mm by 470 mm.

That power becomes heat in the room, so a laboratory that already runs warm should count the −80 °C option twice: once on the electricity bill and once on the air conditioning.

Built into the instrument, or standing beside it

Some evaporation workstations carry their own trap, which keeps the bench tidy and the connection short. In HYSI's catalogue the integrated traps runs at −45 °C on the automated solvent evaporation frames, −50 °C on one refrigerated concentrator, and −60 °C on several models, with a −80 °C option available on one of them.

A separate trap is the better answer in three situations: when the load is larger than a built-in trap was sized for, when the solvent changes between projects, and when one trap has to serve more than one instrument.

Where the instrument the buyer already owns has no trap, the question to asks is whether its gas path gives the buyer a place to fits one. Send the model and HYSI checks the connection and the pump rating before quoting.

The three traps side by side

Model Trap temperature Capacity Power Where it fits
HYSI-CEN-CT110 −50 °C 2000 mL 450 W Routine aqueous and solvent work
HYSI-CEN-CT120 −60 °C 2000 mL 500 W Volatile solvents, lower chamber pressure, shared use
HYSI-CEN-CT130 −80 °C 2000 mL 1000 W Very volatile solvents and low-pressure processes

What to send

Send the solvent or solvent mixture, the volume per batch, the chamber pressure the buyer works at, the pump the buyer intends to uses or already owns, and how many instruments the trap has to serve.

The manufacturer answers with the model, the part number, the connection details and the delivery term, with the trap and the pump as separate items so the cost of each is visible. Where the buyer's solvent makes the trap unnecessary, the page says so.

Related models

Answers before the buyer specifies

Do I need a trap for aqueous samples?

For water alone, a trap is often left out because the vapour is not corrosive. It is still worth having where the pump is expected to last, or where the water load is large enough to affect the vacuum.

How often should I defrost the trap?

Before the ice becomes thick enough to insulate the coil. A trap that is half full of frost condenses less efficiently than an empty one, and the loss shows up as a cycle that gets slower for no obvious reason.

Can I add a trap to a machine that does not have one?

It depends on the gas path of the instrument the buyer already owns. Send the model and HYSI checks the connection point and the pump rating, rather than assuming a bench unit can be dropped in.

Does a colder trap cost more to run?

Yes, and the figures in HYSI's catalogue shows the size of the step. The −50 and −60 °C units draw 450 W and 500 W, while the −80 °C unit draws 1000 W, and that heat ends up in the room.

What is the difference between a built-in trap and a separate one?

A built-in trap is part of the workstation and sized together with it at design stage, which keeps the bench tidy. A separate trap can be matched to the load and replaced on its own, which matters when the solvent or the batch size changes.