+86 186 0328 1443
Ask About a Model
FE-1050T Field Emission Scanning Electron Microscope (FE-SEM) · FE-1050T. Engineering line illustration of analytical instrumentation for M9-4-1, Electron Microscopy, NCS
FE-1050T. Engineering line illustration, not a photograph of the delivered unit.

At a glance

Electron Gun
High-brightness Schottky field-emission gun
Column Technology
Dual-objective lens(近远双磁透镜)
Resolution (High Vacuum)
0.7 nm @ 15 kV; 1.3 nm @ 1 kV
FE-1050TAnalyticalM9-4-1Electron Microscopy

Field Emission Scanning Electron Microscope (FE-SEM) · FE-1050T

Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

Technical Specifications

Electron GunHigh-brightness Schottky field-emission gun
Column TechnologyDual-objective lens(近远双磁透镜)
Resolution (High Vacuum)0.7 nm @ 15 kV; 1.3 nm @ 1 kV
Resolution (Low Vacuum)2.0 nm @ 15 kV
Magnification×2~×1,000,000
Minimum Imaging Voltage10 V
Beam Current1 pA~400 nA, continuously adjustable
Maximum Field of View≥ 80 mm
Stage TravelX 130 mm / Y 130 mm / Z 100 mm
Stage Tilt−70° to +90°
Chamber Ultimate Vacuum5 × 10⁻⁴ Pa
Low Vacuum Mode30 Pa standard; up to 500 Pa optional
Dimensions760 W × 960 D × 1850 H mm
Weight700 kg
Available ExtensionsCathodoluminescence · monochromator / 3-band detector · in-situ Raman · in-situ tensile stage · vacuum cryo system · 3D EBSD

Parameters reproduced from the manufacturer's published page (source). Source grade A1, collected 2026-11-14. Values are reproduced as published, including the original language; no figure has been re-typed or converted.

Key Features

  • 0.7 nm @ 15 kV; 1.3 nm @ 1 kV
  • 2.0 nm @ 15 kV
  • ×2~×1,000,000
  • 10 V

Where This Model Comes From

Sold on this siteNo. The index does not sell laboratory equipment, takes no commission on it and charges nothing. Nothing here carries a HYSI brand, and no sourcing or procurement service is offered. The buyer orders from the manufacturer named in the row below.
Who makes itThe manufacturer. A complete record has not been published for this model, so the page does not name one.
Who the buyer orders fromThe manufacturer. Price, delivery term, freight and customs entry are agreed between the buyer and the manufacturer.
PriceNot published here, and no price range is given: this index does not quote. Price is set by the manufacturer against the configuration, the destination country and the certification required. The manufacturer's own email address and telephone number are in the table above; write to the factory with the model and the quantity. The equipment as supplied may not meet the certification requirements of the buyer's country.
What is on requestThe full parameter table and the certification documents the manufacturer issues.

Certification and Where the Equipment Can Be Sold

Model-level certificatesNone published. No manufacturer record is held for this model.
Management system, held by the manufacturerNone published.
Standards the parameters refer toNot stated on this page.
Markets the certificates on record supportNo market is claimed. A management-system certificate authorises no sale in any market. The EU and EEA require a model-level declaration of conformity and an EU responsible person; the United Kingdom requires UKCA marking; the United States and Canada require UL or CSA listing where the authority having jurisdiction asks for it.
Where the answer comes fromThe manufacturer, in writing. No manufacturer record is published for this model yet.

This index repeats only what the manufacturer has published. Where nothing is published, the row says so rather than leaving a claim standing.

Frequently Asked Questions

What is the FE-1050T Field Emission Scanning Electron Microscope (FE-SEM) · FE-1050T?

FE-1050T is a field emission scanning electron microscope (fe-sem) · fe-1050t listed in the HYSI catalogue. Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

Who should buy the FE-1050T?

It suits laboratories working with m9-4-1, electron microscopy, ncs, typically universities, research institutes, enterprise R&D centres and third-party testing laboratories.

Does this page show a price?

No. This index does not quote and gives no price range. Price is set by the manufacturer against the configuration, the destination country and the certification required. The contact block below carries the maker's own email address and telephone number: write to the factory with the model and the quantity, and the answer comes from the party that sets the price.

Is the voltage compatible with my country?

The manufacturer states the voltage build. A 220 V/50 Hz build, a 187-253 V wide-range build and a 100-240 V build are not interchangeable, and the parameter table states which one a model uses.

What documents are provided with the shipment?

The packing list, the factory inspection report and the customs documents are issued by the manufacturer. FAT and PSI reports depend on the maker and on the project.

The full parameter table and the certification documents the manufacturer issues are obtained from the manufacturer.

Related Products

NX-200S X-Ray Fluorescence Spectrometer (XRF) · NX-200S. Engineering line illustration of analytical instrumentation for M9-2-8, X-Ray, NCS Analytical
NX-200S

X-Ray Fluorescence Spectrometer (XRF) · NX-200S

Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

NX-300FA X-Ray Fluorescence Spectrometer (XRF) · NX-300FA. Engineering line illustration of analytical instrumentation for M9-2-8, X-Ray, NCS Analytical
NX-300FA

X-Ray Fluorescence Spectrometer (XRF) · NX-300FA

Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

ONH-5500 Oxygen/Nitrogen/Hydrogen Determinator · ONH-5500. Engineering line illustration of analytical instrumentation for M9-7-3, Elemental Analysis, NCS Analytical
ONH-5500

Oxygen/Nitrogen/Hydrogen Determinator · ONH-5500

Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

Plasma 1500 Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) · Plasma 1500. Engineering line illustration of analytical instrumentation for M9-2-7, Atomic Spectroscopy, NCS Analytical
Plasma 1500

Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) · Plasma 1500

Specifications as published by the manufacturer (NCS). Parameter names follow international instrument practice; values are reproduced as published.

Ask about a parameter, a source, or a row in the manufacturer index

Questions about what a figure means, where it came from, or why a model is listed as it is are answered by the index. Questions about price, delivery or configuration are answered by the manufacturer; the model page carries the number to call.

Send a question