The load on a freeze dryer is water, not product. A batch of dilute protein solution asks far more of the machine than the same mass of dried plant material, and this is the calculation most first configurations get wrong. Ice capacity, trap temperature and shelf area follow from it.
Freeze drying removes water from a frozen solid by sublimation. The machine has to hold the product below its collapse temperature, keep the chamber pressure below the vapour pressure of ice at that temperature, and condense everything that leaves into a trap that stays cold for the whole cycle. Four figures describe that job, and one of them is almost always missing from a first enquiry.
Ice capacity is the figure that decides whether a batch fits. The benchtop unit in HYSI's catalogue removes up to 10 kg of water in 24 hours.
Estimate the water in the buyer's batch rather than its total mass. Multiply the batch mass by the water fraction, and remember that the figure is quoted per day. A cycle that runs for 36 hours cuts the usable capacity by a third, because the trap is holding ice for the whole time.
Leave headroom. A trap running at its stated maximum has no reserve for the second half of a cycle, and a trap that cannot hold the vapour puts water back into the pump.
The trap has to be colder than anything leaving the chamber will condense at. The standard figure for aqueous work is around −56 °C, which is what the base model carries.
The −80 °C option exists for two cases. One is a product with a low eutectic point that forces a very cold shelf, where the vapour arriving at the trap is correspondingly cold. The other is a formulation carrying a solvent that will not condense at −56 °C.
If a solvent is involved, name it before a model is chosen. It changes the trap and it changes the pump gas path, and both are expensive to change afterwards.
Shelf area sets the batch, and the unit in HYSI's catalogue carries 0.3 m² across five shelves. Depth sets the cycle time.
A deep fill dries from the top down. The dry layer insulates the frozen layer below it, so the last few millimetres take longer than everything above them, and the product at the bottom of the tray may never reach the dryness the method assumes. Fill shallow and use more trays.
Uniformity matters as much as area. Trays that overhang the shelf edge and vials packed against the wall both create cold spots that the cycle programme cannot compensate for.
The catalogue figure is a chamber pressure at or below 10 Pa. What matters is the pressure the sensor is actually reading, because a gauge mounted at the pump reads lower than the chamber under load.
Ask where the sensor sits, and ask whether the pressure is logged through the whole cycle. A single figure at the start of primary drying tells the buyer very little about the hour that matters.
Freeze drying is run as a programme: freeze, hold or anneal, primary drying at a shelf temperature, then secondary drying to pull the bound water. The unit in HYSI's catalogue is programmable with data logging, so a cycle can be repeated and shown.
Treat the log the way the buyer would treat a temperature record from a refrigerator. If a batch has to be released against the cycle, the log is the document that releases it, and it needs a place to live and a retention period.
Pre-freezing is worth planning early. A −86 °C freezer next to the dryer gives the buyer a frozen batch ready to load, which shortens the cycle and protects the product from a slow freeze.
| Item | Figure in HYSI's catalogue | What to check against the buyer's works |
|---|---|---|
| Ice capacity | 10 kg per 24 hours | Batch mass × water fraction, plus headroom, divided by cycle length |
| Trap temperature | −56 °C, with a −80 °C option | The lowest temperature the buyer's product must sit at, and any solvent in the formulation |
| Shelf area | 0.3 m² over 5 shelves | Tray or vial footprint, and the fill depth the buyer's method allows |
| Vacuum | 10 Pa or below, at the chamber | Where the sensor sits, and whether pressure is logged through the cycle |
| Programme and log | Programmable with data logging | How the cycle is recorded, exported and retained |
Send the formulation, the water fraction, the batch mass, the tray or vial the buyer intends to uses, the collapse temperature if the buyer knows it, and the cycle length the buyer's protocol allows.
The manufacturer answers with the model, the part number, the tray sets and the delivery term. Where the water load puts two models in range, the page shows the calculation so the separating figure is visible.
Estimate the water in the batch, not the mass of the batch. A product that is mostly solids puts very little load on the trap. Ice capacity is quoted per 24 hours, so a cycle longer than a day reduces what the same machine can take.
A trap at −56 °C covers aqueous formulations. The colder option matters when the product has a low eutectic point the buyer has to stay below, or when the formulation contains a solvent that will not condense at −56 °C.
Sometimes, and the deciding number is the freezing point of that solvent against the trap temperature. State the solvent before a model is named, because it changes the trap and it changes the pump.
An oven removes water with heat, which also collapses structure and can degrade the product. Freeze drying removes the water from a frozen solid, so the dried material keeps the shape and the surface area it had while frozen.
The tray set, the manifold accessories where fitted, and the vacuum pump. Each is listed as its own item, so the buyer can see what is being paid for and leave out what the laboratory already owns.
Questions about what a figure means, where it came from, or why a model is listed as it is are answered by the index. Questions about price, delivery or configuration are answered by the manufacturer; the model page carries the number to call.
Send a question